AP660 20 kVA ~ 160 kVA

MODEL AP6680 AP66160
Capacity 80 kVA / 80 kW 160 kVA / 160 kW
Numbers of parallel module 1 ~ 4 1 ~ 8
Numbers of redundancy module 0 ~ 3 0 ~ 7
UPS power module 20 kVA / 20 kW
INPUT
Rated voltage 380 V / 400 V / 415 Vac
Voltage range 204 ~ 242 Vac (load ≤ 50%);

242 ~ 277 Vac (50% < load ≤ 70%);

277 ~ 520 Vac (70% < load ≤ 100%)

Rated frequency 50 / 60 Hz (auto-sense)
Frequency range 40 ~ 70 Hz
Power factor ≥ 0.99
Total harmonic distortion (THDI) ≤ 3%
Bypass voltage range Rated output voltage – 40% ~ rated output voltage + 20% (settable via LCD)
OUTPUT
Voltage 380 V / 400 V / 415 Vac
Voltage regulation ± 1%
Frequency Synchronized with utility in mains mode;

50/60Hz ± 0.1% in battery mode

Power factor 1.0
Waveform Pure sine wave
Crest factor 3:1
Total harmonic distortion (THDV) ≤ 1% (linear load); ≤ 5% (non-linear load)
Transfer time 0 ms
Inverter overload capability 110% ~130%: transfer to bypass in 10 min;

130% ~ 150%: transfer to bypass in 1 min;

> 150%: transfer to bypass in 0.5 s

Bypass overload capability ≤ 150%: long time running

> 150%: power off in 10 s

BATTERIES
DC voltage ± 240 Vdc (options: ± 192 Vdc / ± 204 Vdc / ± 216 Vdc / ± 228 Vdc)
Inbuilt battery of standard model 40 × 12 V / 9 Ah for each module
 Charging current 1 ~ 30 A / 60 A (settable via LCD)
SYSTEM
Efficiency ≥ 94%
Display panel 5.7 Inches LCD touch screen
Alarm Battery mode, low battery, fans fault etc.
EMI EN62040-2
EMS IEC61000-4-2 (ESD)
IEC61000-4-3 (RS)
IEC61000-4-4 (EFT)
IEC61000-4-5 (Surge)
COMMUNICAITONS
RS232 / RS485 / USB / dry contacts (standard) Supports Windows® 98/2000/2003/XP/Vista/2008/7/8/10
SNMP (option) Power management from SNMP manager and web browser
OTHERS
Humidity 0~95% RH @ 0~40℃ (non-condensing)
Noise level ≤ 60 dB
Module dimensions (W × D × H) (mm) 482 × 590 × 131
Module weight 28 kg / power module, 27 kg / charger module, 7 kg / monitoring module
UPS dimensions (W × D × H) (mm) 600 × 1000 × 1600 600 × 1000 × 2000
UPS packaged dimensions (W × D × H) (mm) 700 × 1070 × 1760 700 × 1070 × 2160
UPS Net / Gross weight (kg)

Without inbuilt battery and power module

225 / 245 290 / 310
Input / output / bypass breaker Yes Yes